Alarm Notication Settings
Function Command Value Range / Comment Example
Enable SMS to all
users simultane-
ously in case of
alarm
XXXX_SMSALL:ON By default, in case of alarm the
system sends an SMS message
to User 1. If the system does not
receive a successful SMS mes-
sage delivery conrmation in 20
seconds from the recipient, the
SMS message is sent to User 2,
and if there is still no delivery
conrmation received, to Users
3, 4 and 5, but the sequence
will stop as soon as a delivery
conrmation is received. You
may wish to congure the
system to send these messages
to all pre-programmed user
numbers simultaneously when
alarm occurs.
1111_SMSALL:ON
Disable SMS/text
message to all
users simultane-
ously in case of
alarm
XXXX_SMSALL:OFF 1111_
SMSALL:OFF
External Power Supply & Backup Battery Status Notication Settings
Function Command Value Range / Comment Example
Disable SMS/text
message regard-
ing the external
power supply
XXXX_M:OFF The EPIR2 will let you know
when the mains 230V power
supply fails or recovers. In some
remote places where the mains
power supply is unreliable, you
may wish to congure the sys-
tem to ignore these changes.
1111_M:OFF
Enable SMS/text
message regard-
ing the external
power supply
XXXX_M:ON 1111_M:ON
NOTE: The underscore symbol ‘_’ in these instructions represents a space. So when typing an
SMS/text message, replace the underscore symbol with a single space.