5.3.2. Connecting to ELDES conguration server using ELDES Conguration Tool
software
Run ELDES Conguration Tool software.
Press Remote Conguration button.
In the next window, select Connect
to Remote Server (recommended)
and press Next button.
Enter the received IMEI number
in Device IMEI entry.
Press Continue button.
Upon the successfully established
connection, the system prompts
for an administrator password.
By entering a valid administrator
password, the sys tem grants access
to full conguration remotely.
Remote Conguration
Management window displays all
performed conguration actions.
81
82
83
84
5.3.3. Ending the conguration process
Shut down the
Connection with the
Server
After the system conguration is complete, use one of the fol-
lowing methods to end the con guration process:
Press Disconnect button and close ELDES Congura-
tion Tool software;
Wait for the system to reply with an SMS message con-
rming the end of the session;
Shut down the connection with the server at any time
by sending an SMS message.
SMS
SMS text:
XXXX_ENDCONFIG
Example: 1111_ENDCONFIG