User manual
USER MANUAL ELDES ESIM251 V1.0 27
XXXX_
SMSEXTRA:
Z2:SS,SC,
CC,SE,SD
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
3.9.2 Additional possibilities of controlling and conguring controller C1 (relay output)
Normally C1 output can be controlled only by SMS message, as described in chapter 3.6, i. e. by enabling/disabling it for a perma-
nent status or for a preset period. However, you can congure automatic enabling and disabling for a particular hour or control this
function by a call.
3.9.2.1 Settings of an output controlled by calls
When calling on the number of system ESIM251 the call is rejected and no control operations are run. However, when a special
mode is enabled C1 output can be controlled by a call. It can be controlled by all users NO1-NO5, several users or only one of them.
By calling the system you can enable these 3 functions: enable/disable, enable/disable for a certain period or change output status
witheverycall,i.e.onecallenablesthestatus,thenextonedisablesitetc.
The parameters are changed by sending the following SMS message to the system ESIM251:
XXXX–userpassword.ValuestructureisCnVal,whenCniscommandname(2letters),andVal-itsvalue).
Value (CnVal) – table of values
Cn – command
name (2
letters)
Val – possible
command
meaning.
Command
description
Initial factory
default values
Comments
Enabling control
via call
CE 1,2,3,4,5
Control via call mode
is enabled for users
No:1,2,3,4,5
E. g. CE25 means that users NO2 and NO5 will be
able to control the output via call.
CD 1,2,3,4,5
Control via call modes
is disabled for users
No:1,2,3,4,5
CD12345
Disabled for all
users NO1-NO5.
E. g. CD25 means that output control via call is
disabled for users NO2 and NO5.
Enabling/
disabling
conrmation call
(CallBack)
CS 1,2,3,4,5
Conrmation call
mode is enabled for
users No:1,2,3,4,5.
E. g. CS124 means that when users NO1, NO2 and
NO4 control the output via call they will be notied
about a successful output status change by a
conrmation call.
CC 1,2,3,4,5
Conrmation call
mode is disabled for
users No:1,2,3,4,5..
CC12345
Disabled for all
users NO1-NO5.
E. g. CC124 means that when users NO1, NO2 and
NO4 control the output via call the call conrming
about a successful output status change is disabled
and users will not receive calls.
Conrmation
call duration
parameters
CT
1,2,3,4,5;1; s
Conrmation call
is made for users
No:1,2,3,4,5 when the
ouput is turned on.
s- call time in seconds
СT112
СT212
СT312
СT412
СT512
The rst number refers to user number. The second
number is a command and the last number refers
to call time in seconds.
E. g. СT412 means that if conrmation call mode
is enabled, user NO4 will receive a call if he/she is
trying to turn on the relay. The system will call for
2 seconds.
1,2,3,4,5;0; s
Conrmation call
is made for users
No:1,2,3,4,5 when the
output is turned o.
s- call time in seconds
СT108
СT208
СT308
СT408
СT508
The rst number refers to user number. The second
number is a command and the last number refers
to call time in seconds.
E. g. СT408 means that if conrmation call mode
is enabled, user NO4 will receive a call if he/she is
trying to turn o the relay. The system will call for
8 seconds.
Enabling/
disabling
conrmation
SMS
(SMSconrm)
SS 1,2,3,4,5
Conrmation SMS
mode is enabled for
users No:1,2,3,4,5.
E. g. SS124 means that when users NO1, NO2 and
NO4 control the output via call they will be notied
about a successful output status change by a
conrmation SMS message.
Before that the user has to turn on control from a
particular number by using CE command.
SC 1,2,3,4,5
Conrmation SMS
mode is disabled for
users No:1,2,3,4,5.
SC12345
Disabled for all
users NO1-NO5.
E. g. SC124 means that when users NO1, NO2 and
NO4 control the output via call the conrmation
SMS message informing about the successful
output status change is not sent.
XXXX_SMSEXTRA:COC:Value1,Value2,……,ValueN