Service manual

Page 106
© January 2013 Aqua-Hot
®
600-D01 Series Hydronic Heating System Service Manual - Rev. A
APPENDIX D: AQUA-HOT MAINTENANCE
4. Carefully pull the Diesel-Burner away from the Aqua-Hot 4 to 5
inches before rotating the burner, and then remove.
Step 4: Remove The Diesel Burner (continued)
Aqua-Hot Maintenance Procedure:
NOTE: To remove the diesel burner, it may be necessary to disconnect the control and
hi limit thermostats from the diesel-burner’s white thermostat plug.
Figure D4d