Service manual

Page 44
© January 2013 Aqua-Hot
®
600-D01 Series Hydronic Heating System Service Manual - Rev. A
Aqua-Hot unit. Indicator lights on the front panel will illu-
minate red if there is a short circuit, overload, or fault condi-
tion within the system. It also will indicate when circuits are
functioning properly with a green indicator light.
SECTION 5: ELECTRONIC CONTROLLER
Electronic Controller Overview
The electronic controller is an electronic circuit board that
controls the electrical functions of the Aqua-Hot heating
system. All wiring for the switch panel is connected to the
electronic controller, as well as the wiring circuitry from the
Electronic Controller General Facts
Nominal input voltage range ............................ 10.6V to 15V
Idle current ................................................... Approx. 15mA
Low voltage cutoff threshold ....................................... 10.0V
Under voltage lockout delay ..................... Approx. 5 minutes
Input Load Currents
Zone thermostats (each) .................................. Approx. 4mA
Diesel-Burner switch ..................................... Approx. 12mA
Electric Element switch ................................... Approx. 4mA
Engine Preheat switch ..................................... Approx. 4mA
Low-level cutoff switch................................. Approx. 10mA
Control Thermostat ......................................... Approx. 8mA
Low-temperature cutoff switch ....................... Approx. 5mA
Output Current Capacity
Zone fans (each) .................................................... 2.0A max.
Circulation pumps (each) ...................................... 2.0A max.
Engine preheat pump ............................................. 2.0A max.
AC relay ............................................................ 500mA max.
B4+ burner (Webasto) power ................................ 6.0A max.
B1+ burner master control ..................................... 2.0A max.
C1/C7 burner thermostat control ........................... 1.0A max.
Figure 21