Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  148  12/24/2010 
 Old password and length should be 8. 
<newpwd> string type(string should be included in quotation marks). 
  New password and length should be 8. 
Reference Note 
Default value of <oldpwd> is "12345678". 
If module is locked to a specific SIM card through AT+CLCK and 
password lost or SIM state is PH-SIM PUK, user can use the super 
password to unlock it. 
It is not supported temporarily. 
6.2.41 AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications 
AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications 
Response 
+EXUNSOL: (list of supported <exunsol>s) 
OK 
Test Command 
AT+EXUNSOL 
=? 
Parameters 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+EXUNSOL=
<exunsol>,<mod
e> 
Parameters 
<exunsol>  string type(string should be included in quotation marks). 
values are currently reserved by the present document 
"SQ" Signal Quality Report 
 Displays signal strength and channel bit error rate (similar 
 To AT+CSQ) in form +CSQN: <rssi>,<ber>when values change. 
<mode> 
0 disable 
1 enable 
2 query 
Reference 
Note 
6.2.42 AT+CGMSCLASS Change GPRS Multislot Class 
AT+CGMSCLASS Change GPRS Multislot Class 