Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  152  12/24/2010 
the output frequency equals to (26MHz/8)/(period+1). 
<level> 0-100: tone level, which can be converted to duty ratio. 
Reference  Note 
z  We have a 26MHz crystal oscillator. The MAX frequency of PWM is 
26/8=3.25Mhz. 
z  The equation of final frequency and <period> is this: frequency 
=3.25/(period+1), for example, if <period> is set to 100, we get a 
frequency: 3.25/101 = 32.178Khz. 
z  The equation of <level> and duty factor is: duty factor = (level+1). 
6.2.48 AT+ECHO Echo Cancellation Control 
AT+ECHO Echo Cancellation Control 
Response 
+ECHO: MIC:(list of supported <mic>s), ES:( list of supported <es>s), 
SES:(list of supported <ses>s), MODE:(list of supported <mode>s) 
OK 
Test Command 
AT+ECHO=? 
Parameters 
See Write Command 
Response 
+ECHO: (0, <es>, <ses>, <mode>),(1, <es>, <ses>, <mode>),(2, <es>, 
<ses>, <mode>),(3, <es>, <ses>, <mode>) 
OK 
Read Command 
AT+ECHO? 
Parameters 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+ECHO= 
<mic>,<es>[,<ses
>[,<mode>]] 
Parameters 
<mic> audio channel 
0 main audio handset channel 
1 aux audio headset channel 
2 main audio handfree channel 
3 aux audio handfree channel 
<es> echo suppression 
 0-8 (when mic=0or1 default value is 0; when mic=2 or 3 default 
value is 7 ) the bigger the value, the stronger the restraint. 
<ses> selective echo suppression 