Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  176  12/24/2010 
8.2.6 AT+CIPCLOSE Close TCP or UDP Connection 
AT+CIPCLOSE Close TCP or UDP Connection 
Test Command 
AT+CIPCLOSE
=? 
Response 
OK 
Response: 
1) For single IP connection (+CIPMUX=0) 
CLOSE OK 
2) For multi IP connection (+CIPMUX=1) 
<n>, CLOSE OK 
Write Command 
1) If single IP 
connection 
(+CIPMUX=0) 
AT+CIPCLOSE
=<n> 
2) If multi IP 
connection 
(+CIPMUX=1) 
AT+CIPCLOSE
=<id>, [<n>] 
Parameters 
<n> 0 slow close 
1 quick close 
<id>  a numeric parameter which indicates the connection number 
Execution 
Command 
AT+CIPCLOSE 
Response 
If close is successfully: 
CLOSE OK 
If close fails: 
ERROR 
Reference 
Note 
AT+CIPCLOSE only closes connection at the status of TCP/UDP which 
returns CONNECTING or CONNECT OK, otherwise it will return 
ERROR, after the connection is closed, the status is IP CLOSE in single IP 
mode 
8.2.7 AT+CIPSHUT Deactivate GPRS PDP Context 
AT+CIPSHUT Deactivate GPRS PDP Context 
Test Command 
AT+CIPSHUT=? 
Response 
OK 
Execution 
Command 
AT+CIPSHUT 
Response 
If close is successful: 
SHUT OK 
If close fails: 
ERROR 
Reference 
Note 
z  If this command is executed in multi-connection mode, all of the IP 