Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  19  12/24/2010 
If connection successful and non-voice call. 
CONNECT<text> TA switches to data mode. 
Note:  <text> output only if ATX<value> parameter setting with the 
<value> >0 
When TA returns to Command mode after call release 
OK 
If connection successful and voice call 
OK 
Parameters 
<n>    String of dialing digits and optionally V.25ter modifiers dialing 
digits: 
 0-9, * , #, +, A, B, C 
 Following V.25ter modifiers are ignored: 
 ,(comma), T, P, !, W, @ 
Emergency call: 
<n> Standardized emergency number 112 (no SIM needed) 
<mgsm> String of GSM modifiers: 
  I Actives CLIR (Disables presentation of own number 
to called party) 
  i Deactivates CLIR (Enable presentation of own number 
to called party) 
  G  Activates Closed User Group invocation for this call 
only 
   g  Deactivates Closed User Group invocation for this call 
only 
<;>  Only required to set up voice call , return to Command state 
Reference 
V.25ter 
Note 
z  Parameter "I" and "i" only if no *# code is within the dial string 
z  <n> is default for last number that can be dialed by ATDL 
z  *# codes sent with ATD are treated as voice calls. Therefore, the 
Command must be terminated with a semicolon ";" 
z  See  ATX  Command for setting result code and call monitoring 
parameters. 
Responses returned after dialing with ATD 
z  For voice call two different responses mode can be determined. TA
returns "OK" immediately either after dialing was completed or after 
the call is established. The setting is controlled by AT+COLP. Factory 
default is AT+COLP=0, this cause the TA returns "OK" immediately 