Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  213  12/24/2010 
OK 
+FTPPUT:1,<error> 
If mode is 2 and <reqlength> is not 0 
+FTPPUT:2,<cnflength> 
…… //Input data 
OK 
If mode is 2 and <reqlength> is 0, it will respond OK, and FTP session will 
be closed 
OK 
If data transfer finished. 
+FTPPUT:1,0  
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameters 
<mode>  1 for opening FTP put session 
  2 for writing FTP upload data. 
<reqlength> Requested number of data bytes(0-<maxlength>) to be 
transmitted 
<cnflength> Confirmed number of data bytes to be transmitted 
<maxlength> The max. length of data can be sent at a time. It depends on 
the network status. 
<error>  see AT+FTPGET 
Reference 
Note 
When "+FTPPUT:1,1,<maxlength>" is shown, then use AT+FTPPUT=2,
<reqlength> to write data. 
11.2.16 AT+FTPSCONT Save FTP Application Context 
AT+FTPSCONT Save FTP Application Context 
Read Command 
AT+FTPSCONT
? 
Response 
TA returns FTP Application Context, which consists of the following AT 
Command parameters. 
+FTPSCONT:<mode> 
+FTPSERV: <value> 
+FTPPORT: <value> 
+FTPUN: <value> 
+FTPPW: <value> 
+FTPCID: <value> 