Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  24  12/24/2010 
This setting determines whether or not the TA echoes characters received 
from TE during Command state. 
OK 
Command 
ATE<value> 
Parameter 
<value> 0 Echo mode off 
   1 Echo mode on 
Reference 
V.25ter 
Note 
2.2.8 ATH Disconnect Existing Connection 
ATH Disconnect Existing Connection 
Response 
Disconnect existing call by local TE from Command line and terminate call
OK 
Note: OK is issued after circuit 109(DCD) is turned off, if it was previously 
on. 
Execution 
Command 
ATH[n] 
Parameter 
<n> 0 Disconnect ALL calls on the channel the command is 
requested. All active or waiting calls, CS data calls, GPRS call 
of the channel will be disconnected. 
1 Disconnect all calls on ALL connected channels. All active or 
waiting calls, CSD calls, GPRS call will be disconnected. 
(clean up of all calls of the ME) 
2 Disconnect all connected CS data call only on the channel 
the command is requested. (speech calls (active or waiting) 
or GPRS calls are not disconnected) 
3 Disconnect all connected GPRS calls only on the channel 
the command is requested (speech calls (active or waiting) 
or CS data calls are not disconnected. 
4 Disconnect all CS calls (either speech or data) but does not 
disconnect waiting call (either speech or data) on the 
channel the command is requested. 
5 Disconnect waiting call (either speech or data) but does not 
disconnect other active calls (either CS speech, CS data or 
GPRS) on the channel the command is requested. 
(rejection of incoming call) 
Reference 
V.25ter 
Note 