Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  33  12/24/2010 
ERROR 
Parameter 
<value> 0 Restore profile 0 
1 Restore profile 1 
Reference 
V.25ter 
Note 
Parameter impacted by Z command: 
Command  Parameter name  Default value 
ATE  <echo>  0x01 
ATQ  <result>  0x00 
ATV  <format>  0x01 
ATX  <result>  0x04 
AT&C  <behavior>  0x01 
AT&D  <behavior>  0x01 
AT+IFC  <TA_by_TE>  0x00 
AT+IFC  <TE_by_TA>  0x00 
AT+FCLASS  <class>  0x00 
ATS0  <num>  0x00 
ATS3  <char>  0x00 
ATS4  <char>  0x0D 
ATS5  <char>  0x0A 
ATS7  <time>  0x08 
ATS8  <time>  0x32 
ATS10  <time>  0x0E 
2.2.28 AT&C Set DCD Function Mode 
AT&C Set DCD Function Mode 
Response 
This parameter determines how the state of circuit 109 (DCD) relates to the 
detection of received line signal from the distant end. 
OK 
ERROR 
Execution 
Command 
AT&C[<value>] 
Parameter 
<value> 0 DCD line is always ON 
1 DCD line is ON only in the presence of data carrier   
Reference 
V.25ter 
Note 