Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  60  12/24/2010 
3.2.17 AT+CLCK Facility Lock 
AT+CLCK Facility Lock 
Response 
+CLCK: (list of supported <fac>s) 
OK 
Test Command 
AT+CLCK=? 
Parameter 
See Write Command 
Response 
This Command is used to lock, unlock or interrogate a ME or a network 
facility <fac>. Password is normally needed to do such actions. When 
querying the status of a network service (<mode>=2) the response line for 
‘not active’ case (<status>=0) should be returned only if service is not 
active for any <class>. 
If <mode>≠2 and Command is successful 
OK 
If <mode>=2 and Command is successful 
+CLCK: <status>[,<class1>[<CR><LF>+CLCK: 
<status>,<class2>[…]] 
OK 
If error is related to ME functionality: 
+CME ERROR: <err>
Write Command 
AT+CLCK= 
<fac>,<mode> 
[,<passwd> 
[,<class>]] 
Parameters 
<fac> 
 "AO"  BAOC (Barr All Outgoing Calls) 
 "OI"  BOIC (Barr Outgoing International Calls) 
  "OX"  BOIC-exHC (Barr Outgoing International Calls 
except to Home Country) 
  "AI"   BAIC (Barr All Incoming Calls) 
  "IR"  BIC-Roam (Barr Incoming Calls when Roaming 
outside the home country) 
  "AB" All Barring services 
  "AG"    All out oing barring services 
  "AC" All in Coming barring services  
  "FD" SIM card or active application in the UICC (GSM or
USIM) fixed dialling memory feature (if PIN2 
authentication has not been done during the current 
session, PIN2 is required as <passwd>) 
  "SC"  SIM (lock SIM/UICC card) (SIM/UICC asks 
password
in
 MT power-up and when this lock 
command issued) Correspond to PIN1 code. 