Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  83  12/24/2010 
OK 
ERROR 
Parameters 
See Write Command 
Response 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CMUX=<mo
de>[,<subset>[,<
port_speed>[,<N
1>[,<T1>[,<N2>[,
<T2>[,<T3>[,<k>
]]]]]]]] 
Parameters 
<mode>  multiplexer transparency mechanism 
0 Basic option 
<subset> the way in which the multiplexer control channel is set up 
0 UIH frames used only 
<port_speed> transmission rate 
  1 9 600 bits/t 
  2 19 200 bits/t 
  3 38 400 bits/t 
  4 57 600 bits/t 
5  115 200bit/s 
  6 230 400 bits/t 
  7 460 800 bits/t 
  proprietary values, available if MUX NEW PORT 
SPEED FTR is activated 
  8 921 600 bits/t 
  Proprietary values, available if MUX NEW PORT 
SPEED FTR is activated 
<N1> maximum frame size 
1-32768 Default: 127 
<T1> acknowledgement timer in units of ten milliseconds 
1-255 Default:10 (100 ms) 
<N2> maximum number of re-transmissions 
0-100 Default:3 
<T2>  response timer for the multiplexer control channel in units of 
ten milliseconds 
2-255 Default:30 
<T3> wake up response timers in seconds 
1-255 Default:10 
<k> window size, for Advanced operation with Error Recovery 
options 
1-7 Default:2 
Reference 
GSM 07.07 [13] 
Note 
The multiplexing transmission rate is according to the current serial baud 
rate. It is recommended to enable multiplexing protocol under 115200 