Specifications
SIM900 AT Command Manual       
SIM900_AT Command Manual_V1.03  93  12/24/2010 
See Write Command 
Response 
+CCWE: <mode> 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Read Command 
AT+CCWE? 
Parameter 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameter 
<mode>  0 Disable call meter warning event 
  1 Enable call meter warning event 
Write Command 
AT+CCWE=<m
ode> 
Unsolicited result codes supported: 
+CCWV  Shortly before the ACM (Accumulated Call Meter) 
maximum value is reached, an unsolicited result code 
+CCWV will be sent, if enabled by this command. The 
warning is issued approximately when 5 seconds call time 
remains. It is also issued when starting a call if less than 5 s 
call time remains. 
Reference 
GSM 07.07 [13] 
Note 
GSM 07.07 specifies 30 seconds, so SIMCom deviates from the 
specification. 
3.2.56 AT+CBC Battery Charge 
AT+CBC Battery Charge 
Response 
+CBC: (list of supported <bcs>s),(list of supported <bcl>s),(<voltage>) 
OK 
Test Command 
AT+CBC=? 
Parameters 
See Execution Command   
Execution 
Command 
AT+CBC 
Response 
+CBC: <bcs>, <bcl>,<voltage> 