Data Sheet

Smart Machine Smart Decision
Time
Reference Note
This command is used to test PDPs with network simulators. Successful
activation of PDP on real network is not guaranteed.
Refer to AT+CGDATA clarification for more information.
7.2.6 AT+CGDATA Enter Data State
AT+CGDATA Enter Data State
Test Command Response
+CGDATA: list of supported <L2P>s
AT+CGDATA=?
OK
Parameter
See Write Command
Response
CONNECT
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CGDATA=<
L2P> [,<cid>]
Parameters
<L2P> A string parameter (string should be included in quotation
marks) that indicates the layer 2 protocol to be used between the
TE and MT:
"
PPP
"
Point to Point protocol for a PDP such as IP
Other values are not supported and will result in an ERROR
response to the execution Command.
<cid> A numeric parameter which specifies a particular PDP context
definition (see +CGDCONT Command)
Parameter Saving NO_SAVE
Mode
Max Response -
Time
Reference Note
7.2.7 AT+CGPADDR Show PDP Address
AT+CGPADDR Show PDP Address
Response
+CGPADDR: (list of defined <cid>s)
OK
Test Command
AT+CGPADDR=
?
Parameters
See Write Command
SIM800 Series_AT Command Manual_V1.05 205 2014-07-31