Data Sheet

Smart Machine Smart Decision
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CCODE=<
mode>
Parameter
<mode> 0 Code mode compatible with NOKIA
1 Code mode compatible with SIEMENS
Parameter Saving NO_SAVE
Mode
Max Response -
Time
Reference Note
6.2.33 AT+CIURC Enable or Disable Initial URC Presentation
AT+CIURC Enable or Disable Initial URC Presentation
Response
+CIURC: (0,1)
OK
Test Command
AT+CIURC=?
Parameter
See Write Command
Response
+CIURC:<mode>
OK
Read Command
AT+CIURC?
Parameter
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CIURC=<m
ode>
Parameter
<mode> 0 Disable URC presentation.
1 Enable URC presentation
Parameter Saving AT&W_ SAV E
Mode
Max Response -
Time
Reference Note
When module is powered on and initialization procedure is over.
SIM800 Series_AT Command Manual_V1.05 169 2014-07-31