Data Sheet

Smart Machine Smart Decision
URC "Call Ready" will be presented if <mode> is 1.
6.2.34 AT+CPSPWD Change PS Super Password
AT+CPSPWD Change PS Super Password
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CPSPWD=<
oldpwd>,<newp
wd>
Parameters
<oldpwd> String type(string should be included in quotation marks).
Old password and length should be 8.
<newpwd> String type(string should be included in quotation marks).
New password and length should be 8.
Parameter Saving NO_SAVE
Mode
Max Response -
Time
Reference Note
Default value of <oldpwd> is "12345678".
If module is locked to a specific SIM card through AT+CLCK and
password lost or SIM state is PH-SIM PUK, user can use the super
password to unlock it.
It is not supported temporarily.
6.2.35 AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications
AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications
Response
+EXUNSOL: (list of supported <exunsol>s)
OK
Test Command
AT+EXUNSOL=
?
Parameters
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+EXUNSOL=
<exunsol>,<mod
e>
Parameters
<exunsol> String type(string should be included in quotation marks).
values are currently reserved by the present document
"SQ" Signal Quality Report
Displays signal strength and channel bit error rate (similar
to AT+CSQ) in form +CSQN: <rssi>,<ber>when values
SIM800 Series_AT Command Manual_V1.05 170 2014-07-31