Data Sheet

Smart Machine Smart Decision
Response
If format’s value is 0:
Operator:"<Network_Operator_name>",MCC:<MCC>,MNC:<MNC>
,Rxlev:<Rxlev>,Cellid:<CellID>,Arfcn:<Arfcn>[<CR><LF>Operator:
"<Network_Operator_name2>",MCC:<MCC2>,MNC:<MNC2>,Rxlev
:<Rxlev2>,Cellid:<CellID2>,Arfcn:<Arfcn2>[…]]
If format’s value is 1:
Operator:"<Network_Operator_name>",MCC:<MCC>,MNC:<MNC>
,Rxlev:<Rxlev>,Cellid:<CellID>,Arfcn:<Arfcn>,Lac:<Lac>,Bsic:<Bsic
>[<CR><LF>Operator:"<Network_Operator_name2>",MCC:<MCC2
>,MNC:<MNC2>,Rxlev:<Rxlev2>,Cellid:<CellID2>,Arfcn:<Arfcn2>,L
ac:<Lac2>,Bsic:<Bsic2>[…]]
OK
Execution
Command
AT+CNETSCA
N
Parameters
<Network_Operator_name> Long format alphanumeric of network
operator.
<MCC> Mobile country code.
<MNC> Mobile network code.
<Rxlev> Recieve level.
<CellID> Cell identifier.
<Arfcn> Absolute radio frequency channel number.
<Lac> Location area code
<Bsic> Base station identity code
Parameter Saving NO_SAVE
Mode
Max Response 45s
Time
Reference Note
6.2.68 AT+CMNRP Dual Serial Port Feature
AT+CMNRP Dual Serial Port Feature
Response
+CMNRP: (0-1)
OK
Test Command
AT+CMNRP=?
Parameters
See Write Command
Read Command Response
AT+CMNRP? +CMNRP: <mode>
OK
SIM800 Series_AT Command Manual_V1.05 196 2014-07-31