Data Sheet

Smart Machine Smart Decision
Parameters
See Write Command
Response
OK
ERROR
1)For single IP connection
If “AT+CIPSRIP=1” is set, IP address and port are contained.
if <mode>=1
+CIPRXGET: 1[,<IP ADDRESS>:<PORT>]
if <mode>=2
+CIPRXGET: 2,<reqlength>,<cnflength>[,<IP ADDRESS>:<PORT>]
1234567890
OK
if <mode>=3
+CIPRXGET: 3,<reqlength>,<cnflength>[,<IP ADDRESS>:<PORT>]
5151…
OK
if <mode>=4
+CIPRXGET: 4, <cnflength>
OK
2)For multi IP connection
If “AT+CIPSRIP=1” is set, IP address and port is contained.
if <mode>=1
+CIPRXGET: 1[,<id>,<IP ADDRESS>:<PORT>]
if <mode>=2
+CIPRXGET: 2,<id>,<reqlength>,<cnflength>[,<IP
ADDRESS>:<PORT>]
1234567890
OK
if <mode>=3
+CIPRXGET: 3,<id>,<reqlength>,<cnflength>[,<IP
ADDRESS>:<PORT>]
5151…
OK
if <mode>=4
+CIPRXGET: 4, <id>,<cnflength>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
1) If single IP
connection
(+CIPMUX=0)
AT+CIPRXGET
=<mode>[,<reqle
ngth >]
2) If multi IP
connection
(+CIPMUX=1)
AT+CIPRXGET
=<mode>[,<id>,<
reqlength >]
Parameters
<mode>