Data Sheet

Smart Machine Smart Decision
9 AT Commands for IP Application
9.1 Overview
Command Description
AT+SAPBR Bearer settings for applications based on IP
9.2 Detailed Descriptions of Commands
9.2.1 AT+SAPBR Bearer Settings for Applications Based on IP
AT+SAPBR Bearer Settings for Applications Based on IP
Response
+SAPBR: (0-4),(1-3), "ConParamTag","ConParamValue"
OK
Test Command
AT+SAPBR=?
Parameters
See Write Command
Response
OK
If<cmd_type> = 2
+SAPBR: <cid>,<Status>,<IP_Addr>
OK
If <cmd_type>=4
+SAPBR:
<ConParamTag>,<ConParamValue>
OK
Unsolicited Result Code
+SAPBR <cid>: DEACT
Write Command
AT+SAPBR=<c
md_type>,<cid>[
,<ConParamTag
>,<ConParamVa
lue>]
Parameters
<cmd_type>
0 Close bearer
1 Open bearer
2 Query bearer
3 Set bearer parameters
4 Get bearer parameters
<cid> Bearer profile identifier
<Status>
0 Bearer is connecting
1 Bearer is connected
SIM800 Series_AT Command Manual_V1.05 240 2014-07-31