Data Sheet

Smart Machine Smart Decision
Parameters
<IPaddr> Address of the remote host,string type.This
parameter can be either:
- IP address in the format:”xxx.xxx.xxx.xxx”
- Host name solved by a DNS query
<retryNum> The number of Ping Echo Requset to send
1-100 Default: 4
<dataLen> The length of Ping Echo Request data
0-1024 Default: 32
<timeout> The timeout,in units of 100 ms,waiting for a single
Echo Reply
1-600 Default: 100(10 seconds)
<ttl> Time to live
1-255 Default: 64
<replyId> Echo Reply number
<IP Address> IP Address of the remote host
<replyTime> Time,in units of 100 ms, required to receive the
response
Parameter Saving NO_SAVE
Mode
Max Response Time -
Reference Note
z Before sending PING Request the GPRS context must be activated.
z When the Echo Request timeout expires (no reply received on
time), the response will contains <replyTime> setting to 600 and
<ttl> setting to 255.
z When executing this command, if PDP context is deactivated for
some reasons, such as out of service, etc.,the “+PDP: DEACT
URC is reported and the command will end immediately.
10.2.2 AT+CIPCTL Set the Mode When Receiving an IP Packet
AT+CIPCTL Set the Mode When Receiving an IP Packet
Response
+CIPCTL: (list of supported <mode>s)
OK
Test Command
AT+CIPCTL=?
Parameters
See Write Command
Read Command Response
AT+CIPCTL? +CIPCTL: <mode>
SIM800 Series_AT Command Manual_V1.05 243 2014-07-31