Data Sheet

Smart Machine Smart Decision
+FTPLIST: 1,0
If mode is 1 and it is a failed FTP get session:
OK
+FTPLIST: 1,<error>
If mode is 2:
+FTPLIST: 2,<cnflength>
012345678…
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode>
1 For opening FTP get file list session
2 For reading FTP file list
<reqlength> Requested number of data bytes (1-1460) to be read
<cnflength> Confirmed number of data bytes to be read, which may be
less than <reqlength>. 0 indicates that no data can be read.
<error> See “AT+FTPGET”
Parameter Saving NO_SAVE
Mode
Max Response 60 seconds(In case no response is received from server)
Time
Reference Note
When “+FTPLIST: 1,1” is shown, “AT+FTPLIST=2,<reqlength>” can be
used to read data. If the module still has unread data, “+FTPLIST: 1,1”
will be shown again in a certain time.
12.2.24 AT+FTPGETTOFS Download File and Save in File System
AT+FTPGETTOFS Download File and Save in File System
Test Command Response
AT+FTPGETTO OK
FS=?
Response
+FTPGETTOFS: <status>[,<receivedLength>,<writeLength>]
OK
Read Command
AT+FTPGETTO
FS?
Parameters
<status> the process status of downloading and saving File to File System
through FTP
0 not in the process