Data Sheet

Smart Machine Smart Decision
3 output download data
<filename> file name to write data in mode 2. Alphanumeric ASCII text
string up to 64 characters.
<readPosition> position start read data in mode 3.
<readLength> read length in mode 3
<totalLength> The total length of data bytes have been download
<outputLength> total length will be output from serial port
<error> 85 An error related with file system.
Other errors pls see FTPGET.
Parameter Saving NO_SAVE
Mode
Max Response 60 seconds(In case no response is received from server)
Time
Reference Note
Can not use this function when set FTPEXTPUT mode 1
12.2.27 AT+FTPFILEPUT Load File in RAM from File System then Upolad with
FTPPUT
AT+FTPFILEPUT Load File in RAM from File System then Upload with FTPPUT
Test Command Response
AT+FTPFILEPU OK
T=?
Response
If success:
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+FTPFILEPU
T=<mode>[,filena
me]
Parameters
<mode>
0 not use FTPFILEPUT method
1 use FTPFILEPUT method
<filename> file name to write data in mode 1. Alphanumeric ASCII text
string up to 64 characters.
<error> 85 An error related with file system.
Other errors pls see FTPGET.
Parameter Saving NO_SAVE
Mode
Max Response 60 seconds(In case no response is received from server)
Time
Reference Note
Can not use this function when set FTPEXTPUT mode 1
SIM800 Series_AT Command Manual_V1.05 277 2014-07-31