Data Sheet

Smart Machine Smart Decision
If connection successful and voice call
OK
Parameters
<n> String of dialing digits and optionally V.25ter modifiers dialing
digits:
0-9, * , #, +, A, B, C
Following V.25ter modifiers are ignored:
,(comma), T, P, !, W, @
Emergency call:
<n> Standardized emergency number 112 (no SIM needed)
<mgsm> String of GSM modifiers:
I Actives CLIR (Disables presentation of own number to
called party)
i Deactivates CLIR (Enable presentation of own number
to called party)
G Activates Closed User Group invocation for this call
only
g Deactivates Closed User Group invocation for this call
only
<;> Only required to set up voice call , return to Command state
Parameter Saving NO_SAVE
Mode
Max Response 20s(voice call)
Time Timeout set with ATS7 (data call)
Reference Note
V.25ter Parameter "I" and "i" only if no *# code is within the dial string
<n> is default for last number that can be dialed by ATDL
*# codes sent with ATD are treated as voice calls. Therefore, the Command
must be terminated with a semicolon ";"
See ATX Command for setting result code and call monitoring parameters.
Responses returned after dialing with ATD
For voice call two different responses mode can be determined. TA returns
"OK" immediately either after dialing was completed or after the call is
established. The setting is controlled by AT+COLP. Factory default is
AT+COLP=0, this cause the TA returns "OK" immediately after dialing
was completed, otherwise TA will returns "OK", "BUSY", "NO DIAL
TONE", "NO CARRIER".
Using ATD during an active voice call:
When a user originates a second voice call while there is already an active
SIM800 Series_AT Command Manual_V1.05 29 2014-07-31