Data Sheet

Smart Machine Smart Decision
Max Response Time -
Reference Note
14.2.13 AT+POP3SRV Set POP3 Server and Account
AT+POP3SRV Set POP3 Server and Account
Response
+POP3SRV: <pop3ServerLength>,<userNameLength>,<password-
Length>,(range of supported <pop3Port>s)
OK
Test Command
AT+POP3SRV=?
Parameters
See Write Command
Response
+POP3SRV: <pop3Server>,<userName>,<password>,<pop3Port>
OK
Read Command
AT+POP3SRV?
Parameters
See Write Command
Response
OK
If error is related to ME functionality:
ERROR
Write Command
AT+POP3SRV=<po
p
3Server>,<userNa
m
e>,<password>[,<p
o
p3Port>]
Parameters
<pop3Server> POP3 server address, string type. This parameter can
be either:
- IP address in the format: xxx.xxx.xxx.xxx
- Host name to be solved with a DNS query
<userName> The user name to log in POP3 server, string type.
<password> The password to log in POP3 server, string type.
<pop3Port> The port of POP3 server.
1-65535 Default: 110
<pop3ServerLength> The max length of <pop3Server>.
<userNameLength> The max length of <userName>.
<passwordLength> The max length of <password>.
Parameter Saving NO_SAVE
Mode
Max Response Time -
Reference Note
SIM800 Series_AT Command Manual_V1.05 292 2014-07-31