Data Sheet

Smart Machine Smart Decision
Response
OK
If error is related to ME functionality:
ERROR
If POP3 server issues a positive response:
+POP3NUM: 1,<totalNumber>,<totalSize>
If POP3 server issues a negative response:
+POP3NUM: 0
If some error occur:
+POP3OUT: <code>
Execution Command
AT+POP3NUM
Parameters
<totalNumber> The Email number on the POP3 server, decimal
format.
<totalSize> The total size of all Email and the unit is in byte.
<code> The result of logging out POP3 server
1 Normally log out POP3 server
61 Network error
62 DNS resolve error
63 POP3 tcp connection error
64 Timeout of POP3 server response
Parameter Saving NO_SAVE
Mode
Max Response Time -
Reference Note
14.2.16 AT+POP3LIST Get the Specific Email Size
AT+POP3LIST Get the Specific Email Size
Response
+POP3LIST: (range of supported <msgNumber>s)
OK
Test Command
AT+POP3LIST=?
Parameter
See Write Command
Write Command Response
AT+POP3LIST=<m OK
s
gNumber>
If error is related to ME functionality:
ERROR
If POP3 server issues a positive response:
+POP3LIST: 1,<msgNumber>,<size>
If POP3 server issues a negative response:
+POP3LIST: 0
SIM800 Series_AT Command Manual_V1.05 294 2014-07-31