Data Sheet

Smart Machine Smart Decision
0 MIC1
1 MIC2
<quality> record quality
0 low
1 medium
2 high
3 best
Parameter Saving NO_SAVE
Mode
Max Response -
Time
Reference Note
z Record will overwrite the record file with the same ID
z High priority event will stop recording and save record file.URC will
report +CREC: n,<id>,<form>,<time>,<len>
z About 40K FAT space will remain for system use.
z Call setup will stop the record. If record in call, call release will stop
record too.
z Record in call only record remote input, the setting of input path don’t
take effect
z Play in call support low quality WAV record file.
z Location relative setting only take effect when SD card is support and
plugged in
z When DDET is set to 1, record is not allowed in call
z The value of parameter <id> of AT+CREC=7 can not support file path.
z The value of parameter <form> of AT+CREC=1 is invalid if the value
of <id> is file path. The record file format can get from file path.
z Scope of parameter <inputpath> is different among SIM800 series
projects, please refer to chapter 21 for details.
17.2.2 AT+CRECORD Record and Send Data to UART
AT+CRECORD Record and Send Data to UART
Response
+CRECORD: (0,1)
OK
Test Command
AT+CRECORD
=?
Parameters
See Write Command
SIM800 Series_AT Command Manual_V1.05 328 2014-07-31