Data Sheet

Smart Machine Smart Decision
Max Response -
Time
Reference Note
V.25ter If called party has specified a high value for ATS0=<n>, call setup may fail.
The correlation between ATS7 and ATS0 is important
Example: Call may fail if ATS7=30 and ATS0=20.
ATS7 is only applicable to data call.
2.2.22 ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in
Dial String of D Command
ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial
String of D Command
Response
<n>
OK
Read Command
ATS8?
Parameters
See Write Command
Response
OK
ERROR
Write Command
ATS8=<n>
Parameters
<n> 0-255 The value of this register determines how long the modem
should pause when it sees a comma in the dialing string.
Parameter Saving AT&W_SAVE
Mode
Max Response -
Time
Reference Note
V.25ter No effect in GSM
2.2.23 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
Response
<n>
OK
Read Command
ATS10?
Parameters
See Write Command
Write Command Response
ATS10=<n>
This parameter setting determines the amount of time that the TA will
SIM800 Series_AT Command Manual_V1.05 41 2014-07-31