Data Sheet

Smart Machine Smart Decision
Mode
Max Response -
Time
Reference Note
V.25ter The Command is applied for Command state;
In <format> parameter, "0 parity" means no parity;
The <parity> field is ignored if the <format> field specifies no parity and
string "+ICF: <format>,255" will be response to AT+ICF? Command.
2.2.40 AT+IFC Set TE-TA Local Data Flow Contro
l
AT+IFC Set TE-TA Local Data Flow Control
Response
+IFC: (list of supported <dce_by_dte>s),(list of supported
<dte_by_dce>s)
OK
Test Command
AT+IFC=?
Parameters
See Write Command
Response
+IFC: <dce_by_dte>,<dte_by_dce>
OK
Read Command
AT+IFC?
Parameters
See Write Command
Response
This parameter setting determines the data flow control on the serial
interface for data mode.
OK
Write Command
AT+IFC=<dce_b
y_dte>[,<dte_by
_dce>]
Parameters
<dce_by_dte> Specifies the method will be used by TE at receive of
data from TA
0 No flow control
1 Software flow control
2 Hardware flow control
<dte_by_dce> Specifies the method will be used by TA at receive of data
from TE
0 No flow control
1 Software flow control
2 Hardware flow control
Parameter Saving AT&W_SAVE
Mode
SIM800 Series_AT Command Manual_V1.05 52 2014-07-31