Data Sheet

Smart Machine Smart Decision
3.2.12 AT+CSCS Select TE Character Set
AT+CSCS Select TE Character Set
Response
+CSCS: (list of supported <chset>s)
OK
Test Command
AT+CSCS=?
Parameters
<chset> "GSM" GSM 7 bit default alphabet (3GPP TS 23.038);
"UCS2" 16-bit universal multiple-octet coded character set
(ISO/IEC10646); UCS2 character strings are converted to
hexadecimal numbers from 0000 to FFFF; e.g.
"004100620063" equals three 16-bit characters with decimal
values 65, 98 and 99
"IRA" International reference alphabet (ITU-T T.50)
"HEX" Character strings consist only of hexadecimal
b
ers from 00 to FF;
"PCCP" PC character set Code
"PCDN" PC Danish/Norwegian character set
"8859-1" ISO 8859 Latin 1 character set
Response
+CSCS: <chset>
OK
Read Command
AT+CSCS?
Parameters
See Test Command
Response
Sets which character set <chset> are used by the TE. The TA can then
convert character strings correctly between the TE and ME character sets.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CSCS=<chse
t>
Parameters
See Test Command
Parameter Saving AT&W_SAVE
Mode
Max Response -
Time
Reference
3GPP TS 27.007
Note
[13]
SIM800 Series_AT Command Manual_V1.05 68 2014-07-31