SM DNGDCI 2-E.1 GB
12.9.13 Jumper Settings
12.9.13.1 Indoor Unit Controller
0 = Open Jumper (disconnect jumper).
1 = Close Jumper (connect jumper).
Self test Jumper – J1
OPERATION J1
SELF-TEST 1
NORMAL 0
Compensation Jumper – J2
Model J2 (Default) Compensation
WNG/WNG18/WNG30/WSA 0 Activated
PXD/AC/NPXD 1 Deactivated
LS/K/KS/AS/AD/DNG/KN 1 Activated
DNG series are defined by “family+ model”:
Family + model
Jumper setting
New family definition Model definition
J8 J7 J6 J5 J4 J3
KS+A 0 0 0 1 0 1 DNG A
LS+A 0 0 0 1 1 0 DNG B
KS+C 1 0 0 1 0 1 DNG C
KS+D 1 1 0 1 0 1 DNG D
Model selection Jumper – J7, J8
Model J8 J7
A
B
C
D
0 0
0 1
1 0
1 1
J9- Presence Detector /Power Shedding
OPERATION J9
Presence Detector 0
Power Shedding 1
Jumper – J10