mains (according to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines
connected directly to the mains.
Only a qualified person can
connect the appliance to the
electricity supply.
1. Open the mains terminal cover (D).
D
E
F
2. Put the connection cable into the
supplied rings (E).
This is to prevent the cable from
rubbing against the drawer. The
connection cable is on the housing
side.
3. Install the cable grip (F).
4. Connect the terminal as in the
illustration.
5. Put the cable into the strain relief
clamp.
6. Close the mains terminal cover.
7. Do the electrical connections as in the
connection illustration.
Phase definitions: L1, L2, L3 (or R, S,
T).
Voltage: 400V
400V3N
400V2N
8. Secure the cable grip.
14. ENERGY EFFICIENCY
14.1 Product Fiche and information according to EU 65-66/2014
Supplier's name Electrolux
Model identification
EBSL7CN
EBSL7EEV
EBSL7SP
Energy Efficiency Index 97.6
Energy efficiency class A
Energy consumption with a standard load, conven-
tional mode
0.93 kWh/cycle
Energy consumption with a standard load, fan-
forced mode
0.83 kWh/cycle
Number of cavities 1
Heat source Electricity
ENGLISH
37