SPLIT AIR-CONDITIONER OWNER'S MANUAL AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www.palsonic.com.au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 Thank you for selecting super quality Air Conditioner. To ensure satisfactory operation for many years to come, this Owner's Manual should be read carefully be fore using your air conditioner. After reading. store it in a Safe place.
CONTENTS Safety Precautions .................................................................................................................... 1 Identification of Parts ................................................................................................................. 2 Remote Controller ..................................................................................................................... 4 Operation Instructions ............................................................
Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Be sure to follow this instruction. The feature of the appliance, instead of a fault. Grounding is essential. Pay attention to such a situation. Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc. Use correct power supply in accordance with the rating plate requirement Otherwise, serious faults or hazard may. occur or a tie maybe break out.
Identification of parts Indoor unit Air intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louvre Horizontal Adjustment Louvre Charcoal Filter (optional) Electrostatic Filter (optional) Air Filter Remote Controller Air Intake Outdoor unit Drain Hose Note: Condensate water drains at COOLING or DRY operation Pipes and Power Connection Cord Air Outlet The figures in this manual are based on the external view of a standard model Consequently, the shape may differ from that of t
Identification of parts Operating and Display Signal Receives Sleep Indicator Receive signal from the remote controller. It lights up during the set sleep function. Timer Indicator It lights up during the set time. Power Indicator It lights up when power supply is on. Run Indicator It is on during operation. The above operating sketch map is suitable for E, F, G, H, J, K, M, N series.
Remote controller Remote controller The remote controller transmits signals to the system. Signal Transmitting Window Setting Display ON/OFF button Used to start and stop operation when pressed. transmitting display time setting display temperature setting display Transmits signals to the system setting temperature adjustment display (During feel mode) TIMER button Used to select TIMER operation.
Remote controller Remote controller I How to Insert the Batteries Please slide and remove the cover. Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Slide the cover upwardly in the direction of the arrow Reattach the cover by sliding it back into position. 2 Exchange the batteries. 3 Install the cover. Attention to the - and + marks Note: Use 2 LR03 AAA (1.5 volt) batteries.
Operation instructions FEEL mode operation procedure Operates by selecting automatically the operation mode ( HEAT, DRY, FAN , COOL ) depending on the room temperature during starting. With the remote controller pointing towards the air conditioner. Turning on Press ON/OFF button, when the appliance receives the signal, the RUN indicator of the indoor unit lights up. 1 SLEEP TIMER ON TIMER OFF When the unit is not at FEEL mode. Selecting FEEL mode Press the MODE select button.
Operation instructions TIMER mode It is convenient to set the timer on with the TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. Timer Setting SLEEP TIMER ON TIMER OFF When the remote controller is off, press the TIMER button to set a switch-on timer, press again, the setting will be cancelled.
Maintenance Front panel maintenance Air filter maintenance Cut off the power supply It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting from power supply Clean it as follows: a Stop the appliance and remove the air filter. Grasp position "a" an pull outward to remove the front panel. 1 a 2 Wipe with a soft and dry cloth. Use a dry and soft cloth to clean it.
Protection Operating condition Noise pollution The protective device may trip and stop the appliance in cases listed below. Install the air conditioner at a place that can bear its weight in order to operate more quietly. Outdoor air temperature is over 240C HEATING Outdoor air temperature is below -70C Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbours.
Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis Does not run. If the plug is not properly plugged in. If batteries in the remote controller are exhausted. If the protective device works to protect the appliance. If the protector trip or fuse is blown. No cooling or heating air. Are the intakes and outlets of the air conditioner blocked? Is the temperature set properly? Is the air filter dirty? Ineffective control.
Installation instructions Distance from ceiling should be over 50 mm Installation diagram Distance from wall should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2500mm Air intake distance from the wall should be over 250mm Air intake distance from the wall should be over 250mm air NOTE ou tl sh et dis ou ld tanc be e ov from er 50 the 0m wa m l ov er 25 0m m l Above figure is only a simple presentation of the unit, it may not match the external ap
Installation instructions Connecting the Cable Front panel Wiring between the indoor and outdoor units: Terminal (inside) 1) Remove the PCB cover from the indoor unit; 2) Refer to the wiring diagram attached to indoor unit when connecting cords to indoor unit terminals; 3) Reinstall the PCB cover. Be sure that side B is facing outside.
Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws. Inspect if the mounting plate is well fixed. Then drill a hole for piping.
Installation instructions NOTE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Piping Thermal Insulation: Thermal insulation a .Place the drain hose under the piping. b. Insulation material use polythene foam over 6mm in thickness. Large pipe Note: Drain hose is prepared by user. Power cord Drain pipe should point downwards for easy drain flow.
Installation instructions 4. Connecting the Cable Front panel Terminal (inside) Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. Cabinet Indoor unit Chassis Note: For some models, it is necessary to remove the cabinet to connect to indoor unit terminal. Outdoor Unit 1) Remove the access door from the unit by loosening the screw.
Installation instructions Outdoor unit installation 1. Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure shown. Washer Drain port 2.
Installation instructions How to Purge Air Tubes: (1) Unscrew and remove caps from 2 and 3-way valves. (2) Unscrew and remove cap from service valve. (3) Connect vacuum pump flexible hose to the service valve. (4) Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5). With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop vacuum pump. (6) Open 2-way valve 1/4 turn then close it after 10 seconds.
AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www.palsonic.com.au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 1130010274 1.