Service manual
2-4
PRODUCT DATA SHEET
SM KN DCI 2-E.2 GB
2.4 KN 80 DCI
Model Indoor Unit KN-80 DCI
Model Outdoor Unit GC-80 DCI
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity
(1)
Btu/hr 27280(6800~30000) 30690(5110~34100)
kW 8.0(2.0-8.8) 9.0(2.5~10.0)
Power input
(1)
kW 2.65(0.5-3.2) 2.60(0.5~3.1)
EER (Cooling) or COP(Heating)
(1)
W/W 3.01 3.46
Energy efficiency class B B
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 12.5 12.3
Starting current A 15
Circuit breaker rating A 20
INDOOR
Fan type & quantity Centrifugal x 1
Fan speeds H/M/L RPM 580/540/500 580/540/500
Air flow
(2)
H/M/L m3/hr 1200/1100/1000 1270/1170/1070
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 53/51/49
Sound pressure level
(4)
H/M/L dB(A) 46/44/42
Moisture removal l/hr 3
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 840*840*300
Weight kg 48
Package dimensions WxHxD mm 1011*931*333
Packaged weight kg 54
Units per pallet units 5
Stacking height units 5 levels
OUTDOOR
Refrigerant control EEV
Compressor type,model Two Rotary,Mitsubishi TNB220F
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 850
Air flow H/L m3/hr 3600
Sound power level H/L dB(A) 66
Sound pressure level
(4)
H/L dB(A) 56
Dimensions WxHxD mm 950x412x835
Weight kg 66
Package dimensions WxHxD mm 1080x477x910
Packaged weight kg 73.5
Units per pallet Units 2
Stacking height units 2 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 2.75kg/7.5m
Additional charge per 1 meter g/m No Need
Connections between units
Liquid line In.(mm) 3/8”(9.53)
Suction line In.(mm) 5/8”(15.88)
Max.tubing length m. Max.30
Max.height difference m. Max.15
Operation control type Remote control
Heating elements (Option) kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
CONTENT