Service manual

12-3
TROUBLESHOOTING
Revision Y06-01
Service Manual - WNG/LEX DCI
12.3 Judgment by Indoor/Outdoor Unit Diagnostics
Enter diagnostics mode - press for five seconds Mode button in any operation mode.
Acknowledgment is by 3 short beeps and lights of COOL and HEAT LEDs. Then, every short
pressing of Mode button will scroll between Indoor and Outdoor unit diagnostic modes by the
acknowledgment of 3 short beeps and lighting of COOL and HEAT LED s.'
During the Outdoor unit diagnostics all four Indoor LED’s, (STBY, Operate, Filter and Timer)
are blinking. When Indoor diagnostics is displayed, all four LED’s (STBY, Operate, Filter and
Timer) are ON.
When system enters diagnostics mode, only one fault code is shown. Order of priority is from
the lower to the higher number. Diagnostics is continuously ON as long as power is ON. The
current system operation mode will not be changed.
If no fault occurred in the system, no fault code will be displayed during normal operation
mode. The last fault code will be displayed even if the system has recovered from that
fault. The last fault will be deleted from the EEPROM after the system has exit diagnostics
mode.
In diagnostics mode, system fault / status will be indicated by blinking of Heat d Cool LEDs.
The coding method will be as follows:
Heat LED will blink 5 times in 5 seconds, and then will be shut off for the next 5 seconds. Cool
LED will blink during the same 5 seconds according to the following Indoor / Outdoor unit
tables:
Note: 0 – OFF, 1-ON
12.3.1 Indoor unit Diagnostics
No Problem 54321
1 RT-1 is disconnected 00001
2 RT-1 is shorted 00010
3 RT-2 is disconnected 00011
4 RT-2 is shorted 00100
5 Reserved 00101
7 Communication mismatch 0 0111
10 Reserved 0 1 0 1 0
11 Outdoor Unit Fault 01011
17 Defrost protection 10001
19 Outdoor Unit Protection 1 0 0 1 1
20 Indoor Coil HP Protection 10100
21 Overflow Protection 1 0 1 0 1
22 Reserved
24 EEPROM Not Updated 11000
25 Bad EEPROM 1 1 0 0 1
26 Bad Communication 11010
27 Using EEPROM data 11011
28ModelA 11100
29
18
8 No Communication 0 1 0 0 0
No Encoder 0 1 0 0 19
... Reserved
30 Model C 11110
31 Model D 1 1111
Model B 1 1 1 0 1
Deicing Protection 1 0 0 1 0
CONTENT
WNG/LEX DCI