Service manual

PRODUCT DATA SHEET
2.3.9 PXD 18 DCI Specifications
Model Indoor Unit / Type PXD 18 DCI Floor/ceiling
Installation Method FLARE
Power Supply V/Ph/Hz 220-240 / 1/ 50
INDOOR
Fan Type & Quantity Centifugal *2
Airflow
(2)
Cooling / Heating
H/M/L m
3
/hr 870 750 600
Sound Power Level
(3)
Cooling / Heating
L - H dB (A) 56 - 65
Sound Pressure Level
(4)
Cooling / Heating
L - H dB (A) 45 - 51
Condensate Drain Tube I.D. mm 16
Dimensions W/H/D mm 1200 630 190
Weight kg 30
Package Dimensions W/H/D mm 1270 710 280
Stacking Height Units 7
Heating Elements kW N/A
Moisture Removal L/hr 2
2.3.10 LS 35 DCI Specifications
Model Indoor Unit / Type LS 35 DCI / Ducted
Installation Method FLARE
Power Supply V/Ph/Hz 220-240 / 1/ 50
INDOOR
Fan Type & Quantity Centifugal *2
Airflow
(2)
Cooling / Heating
H/M/L m
3
/hr 590 50 400
Sound Power Level
(3)
Cooling / Heating
L - H dB (A) 52 - 59
Sound Pressure Level
(4)
Cooling / Heating
L - H dB (A) 35 - 42
Condensate Drain Tube I.D. mm 16
Dimensions W/H/D mm 860 245 680
Weight kg 30
Package Dimensions W/H/D mm 1055 305 728
Stacking Height Units 6
Heating Elements kW N/A
Moisture Removal L/hr 1.3
NOTE:
1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
Revision 0 2-7