Service manual

25
35
50
25+25
25+35
25+50
35+35
35+35
25+25+35
25+25+50
25+35+35
25+35+50
35+35+35
35+35+50
PERFORMANCE DATA
5. PERFORMANCE DATA
5.1 Outdoor Unit Trio DCI Combinations (Based on WNG)
5.1.1 Cooling
Model
Cooling Capacity [KW] Power Consumption [W]
COP
Nom.
Energy
Efficiency
Class
A B C Nom. Min. Max. Nom. Min. Max.
9
- - 2.50 2.50 1.30 3.70 685 500 1,025 3.65 A
12
- - 3.50 3.50 1.30 4.40 968 500 1,223 3.62 A
18
- - 5.00 5.00 1.49 5.93 1,393 566 1,656 3.59 A
9+
9
- 2.54 2.54 5.08 1.86 6.56 1,498 683 1,856 3.39 A
9+
12
- 2.57 3.42 5.99 1.86 7.73 1,783 683 2,541 3.36 A
9+
18
- 2.44 4.88 7.32 1.86 9.00 2,203 659 3,046 3.32 A
12+12
- 3.46 3.46 6.92 1.86 9.00 2,075 683 2,246 3.33 A
12+18
- 2.93 4.39 7.32 1.86 9.00 2,203 659 3,055 3.32 A
25+25+25
9
+9+9
2.40 2.40 2.40 7.20 2.69 8.98 2,240 949 3,049 3.21 A
9+9+12
2.20 2.20 2.93 7.33
2.69 9.00 2,281 949 3,157 3.21 A
9+
9+18
1.83 1.83 3.66 7.32 2.69 9.00 2,278 962 3,097 3.21 A
9+
12+12
1.99 2.66 2.66 7.31 2.69 9.00 2,275 949 3,097 3.21 A
9+
12+18
1.69 2.25 3.37 7.31 2.69 9.00 2,275 962 3,061 3.21 A
12+12+12
2.44 2.44 2.44 7.32 2.69 9.00 2,278 990 3,085 3.21 A
12+12+18
2.09 2.09 3.13 7.30 2.69 9.00 2,272 962 3,086 3.21 A
Nominal Indoor Units Combination
Revision 0 5-1