2.5.5 Align the element air connections with the passages in
the spider and attach the element to the spider with
the appropriate fasteners. See Tablel. Make sure the
element fully engages the register in the spider.
Use only the proper grade and number of fas-
teners. Using commercial grade fasteners
(Grade 2) in place of Grade 8 fasteners may
result in failure of the fasteners under load,
causing personal injury or equipment dam-
age.
TABLE 3
AIR CONNECTIONS FOR VC ELEMENTS
SIZE AIR TUBE WASHER AIR TUBE WASHER
11.5VC500 201402 72 x 15 412178-02 412324-01
14VC500 201302 72 x 11 412178-03 412324-02
16VC600 201302 72 x 11 412178-03 412324-02
20VC600 201302 72 x 11 412178-03 412324-02
24VC650 201286 72 x 12 412178-05 412324-03
28VC650 201286 72 x 12 412178-05 412324-03
33VC650 201284 72 x 13 412178-06 412324-04
37VC650 201284 72 x 13 412178-08 412324-04
42VC650 201284 72 x 13 412178-06 412324-04
14VC1000 201302 72 x 11 412178-03 412324-02
16VC1000 202408 72 x 11 412178-03 412324-02
20VC1000 201302 72 x 11 412178-03 412324-02
24VC1000 201286 72 x 12 412178-05 412324-03
32VC1000 201286 72 x 12 412178-05 412324-03
38VC1200 201284 72 x 13 412178-06 412324-04
42VC1200 201284 72 x 13 412178-06 412324-04
46VC1200 202081 72 x 13 412178-07 412324-04
52VC1200 202751 72 x 14 412178-08 412324-05
51VC1600 304213 72 x 14 412178-09 412324-05
60VC1600 304213 72 x 14 412178-18 412324-06
66VC1600 - - 412178-04 412324-06
76VC1600 - - 412178-04 412324-06
76VC2000 - - 412178-04 412324-06