Specifications
VC 5000 (PDF FORMAT) 12 ©Copyright Eaton Corp., 2010. All rights reserved.
2.7.1.6 If a flow control valve is used, it must have free flow
(indicated by an arrow on the valve body) directed
away from the element.
2.7.1.7 The final connection to the rotorseal MUST be made
with flexible hose and place no radial load upon the
rotorseal.
Do not use rigid pipe at the connection to the
rotorseal. Rigid piping will result in excessive
loads on the rotorseal bearings, shortening
life.
Maximum applied air pressure is 125 psig
(8.5 bar). Operation at pressures exceeding
125 psig may result in damage to the element.
Consult the factory if operation at pressures
greater than 125 psig is desired.
Figure 12
3.0 OPERATION
Exceeding the operating limits described in
this section may result in personal injury or
equipment damage.
3.1 Torque, RPM and Pressure Limits
3.1.1 The developed torque is directly proportional to the
applied air pressure. If the developed torque seems
inadequate, check for oil, grease or dust contamina-
tion.
Maximum applied air pressure is 125 psig (8.5
bar). Operation at pressures exceeding 125
psig may result in damage to the element.
Consult the factory if operation at pressures
greater than 125 psig is desired.
TABLE 4
MAXIMUM SAFE OPERATING SPEEDS
Size (Narrow)
Maximum
RPM
Size (Narrow)
Maximum
RPM
Size (Wide)
Maximum
RPM
Size (Wide)
Maximum
RPM
11.5VC500 1800 28VC650 1000 14VC1000 1800 42VC1200 670
14VC500 1500 33VC650 900 16VC1000 1400 46VC1200 600
16VC600 1400 35VC650 900 20VC1000 1300 52VC1200 550
20VC600 1200 37VC650 800 24VC1000 1250 51VC1600 550
24VC650 1050 42VC650 800 28VC1000 1100 60VC1600 520
32VC1000 1050 66VC1600 480
38VC1200 740 76VC1600 275
76VC2000 275