3.
Multi protective function
3.1 Anti-freezing protecting control:
When the ambient temperature is low while in Cooling Mode, the compressor and water
pump will stop working if the copper coil temperature is too low. When the copper coil
temperature increases, the protection will be stopped automatically.
3.2Water-full protection:
When the water level in the internal water tank is surpassing the maximum level, the
unit will alert automatically and E4 will be displayed on the LED screen. Please
discharge water. In the machine according to “Water Drainage” section.
3.3 Compressor protection
Compressor has an overheating protection function and may stop to prevent
compressor damage. Also the compressor runs under a 3 minute delay protection
function.
OPERATION MODES
ElectrIQ Airflex 15 is the most flexible fully featured air conditioner on the
market.
Combined with the optional Airflex Comfort Kit that enable using this Air
Conditioner in spaces where traditionally there is not enough space to fit an air
conditioner: Server Rooms, Small office spaces etc.
Airflex 15 can be placed outside the room to cool, on balconies, corridors,
mezzanines etc. cooling or heating the space via the air comfort grill which acts
also as a wired remote or can be used with existing remote.
Also by moving the unit outside the room the noise of the portable unit is
significantly decreased.