USER MANUAL COMPRESSOR DIGITAL DEHUMIDIFIER CD10L – 10 litres per day CD20L – 20 litres per day Thank you for choosing electriQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www.electriQ.co.
CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 9 WATER DRAINAGE 11 CARE AND MAINTENANCE 12 TROUBLESHOOTING 13 TECHNICAL DATA 14 1
SAFETY INSTRUCTIONS IMPORTANT • Carefully read the instructions before operating the unit • This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used.
• • • • • • • • • • • • • R290 has a low GWP (Global Warming Potential) of 3. The CD10L contains about 45g of R290 refrigerant gas. The CD20L contains about 85g of R290 refrigerant gas. Do not use or store the CD20L in an unventilated space with an area smaller than 4.1m 2 per unit. Do not use or store the CD10L in an unventilated space with an area smaller than 2.2m2 per unit.
QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER 4
INSTALLATION Remove any water from the water tank before starting the unit. In order to save energy, do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. To reduce noise levels: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. The CD10L and CD20L dehumidifiers use compressor technology to extract water from the environment.
PARTS CD10L CD20L 1. Front Case 4. Control Panel 7. Water Tank 2.Dry Air Outlet 5.Air Inlet/ Filter housing 8.Wheels / Feet 3.Handle 6.Back case 9.Power supply cord HUMIDITY LEVEL & TIMER 2 DIGIT DISPLAY The led indicator performs the following functions: 1. When the unit is plugged in, it will indicate the humidity level of the room 2. When the up or down buttons are pressed, it will indicate the desired humidity set 3.
CONTROL PANEL CD10L CD20L 2 7 8 3 6 45 3 2 1 E B E F F A D LED Indicators Power indicator 1 Timer 2 Water tank full 3 Fan speed low 4 5 6 7 8 C B A Fan speed high Laundry mode Defrost Compressor Running BUTTONS A Turn the appliance ON/OFF POWER B TIMER C FAN SPEED D With the unit on standby: Press the timer button repeatedly to set the delay until it turns on. With the unit running: Press the timer button repeatedly to set the delay until it turns off.
QUICK REFERENCE GUIDE Power Button: Press to turn the dehumidifier on and off. Timer: Press the timer button to set the timer (1-24 hrs, start/stop timer). While the unit is running: The number displayed will represent the number of hours the unit will run before turning off. This will remain unaffected if unit goes in to defrost mode or the tank is emptied then reinserted. While the unit is in standby: The number displayed represents the period in hours after which the unit will start.
OTHER FEATURES AND INDICATORS TANK FULL LIGHT When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation. AUTO DEFROST When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
POSITIONING THE DEHUMIDIFIER A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small office applications and any commercial or industrial use will invalidate the warranty. Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment.
WATER DRAINAGE When the water tank is full, the unit will stop automatically. When this happens the TANK FULL red light will show on the control panel, and the unit will bleep. NOTE: Only empty the water tank when it is full or before moving or storing the unit. There are two ways to dispense collected water. 1. USE THE TANK When the tank is full, the unit will automatically stop running, and the Tank Full indicator will flash. Slowly pull out the tank.
CARE AND MAINTENANCE Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. 1. CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit.
FREQUENTLY ASKED QUESTIONS Why doesn’t the dehumidifier seem to extract much water if the temperature is low? This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range.
TECHNICAL DATA Model Voltage CD10L-V3 Dehumidifying capacity CD20L-V3 220-240V~50Hz 220-240V~50Hz 10 L / day (at 30⁰ C / 80%RH) 1 280 W 1.4 Amps 2 litres 30%~90% R290, 45 grams 150 2.6 / 1.0 MPa ≤42 1.8 meters 276x185x480 20 L / day (at 30⁰ C / 80%RH) 2 380 W 2 Amps 5 litres 30%~90% R290a, 85 grams 150 / 200 (Low/ High) 2.6 / 1.0 MPa ≤47 1.