USER MANUAL electriQ 9,200 BTU PORTABLE INDUSTRIAL AIR CONDITIONER CMAC10M Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY INFORMATION 3 FEATURES 5 APPLIANCE DIAGRAM 5 INSTALLATION 6 OPERATION 7 EMPTYING THE INTERNAL WATER TANK 8 CLEANING AND MAINTENANCE 8 TROUBLESHOOTING 9 SUPPORT 10 TECHNICAL SPECIFICATION 10 2
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit • This appliance is for indoor use only. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. • This air conditioner has been tested and is safe to use.
• Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel. • Always place the unit on a dry and stable surface. • The appliance should not be installed in laundry or wet rooms. • The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater). • R290 refrigerant gas complies with European environmental directives.
FEATURES • • • • • The CMAC10M is great for Rooms up to 26 m2. 2 speed fan: Balancing quiet operation with performance. Simple operation. Castors for Enhanced Portability. Durable metal casing.
INSTALLATION COLD AIR OUTLETS 1. Line up the dimple on the Elbow with the notch on the Hose connector on the top of the air conditioner. 2. Rotate anticlockwise until a click can be heard, indicating the elbow has locked into place. 3. Insert the Cold Air Hose into the Elbow, again lining up the dimple with the notch in the Elbow. 4. Rotate the pipe anticlockwise to fix it in place. 5. The pipe can then be extended and pointed in the desired direction. HOT AIR OUTLET 1.
OPERATION Turn the control switch to select your desired fan speed between Low and High. When you have finished, turn the control switch back to the Off position. The unit can also be used as a dehumidifier by not using the hot air hose. We advise on setting the unit up with continuous drainage when using it as a dehumidifier. MULTI PROTECTIVE FUNCTIONS FROST PROTECTION If the temperature of the exhaust is too low, the machine will automatically stop operating until the temperature has risen.
EMPTYING THE INTERNAL WATER TANK MANUAL DRAINAGE: When the internal water tank is full the unit will stop working. Shut off the unit and unplug. Try not to move the appliance as this may cause the water in the internal tank to spill out. Remove the water tank from the base of the unit and empty into a sink or drain. Replace the water tank in the unit before plugging back in and restarting operation.
TROUBLESHOOTING Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here. Problems The air conditioner does not work. The cooling effect is not good Reasons Solutions There is no electricity. Turn it on after connecting it to a socket with electricity. FULL indicator is illuminated Discharge the water inside.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call the number below, or complete the online form. 0330 390 3061 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full.