USER MANUAL MULTISTAGE PORTABLE AIR PURIFIER TRUE HEPA, VOC FILTER, UV LAMP, TIO2 PHOTO CATALYST (PCO), PLASMA IONISER AND ADVANCED ACTIVATED CARBON FILTER EAP400D Thank you for choosing this innovative electriQ Air Purifier. Please read before using the product and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY INSTRUCTIONS 3 INDOOR POLLUTANTS 4 INTRODUCTION 5 DIAGRAM 5 OPERATION 6 BEFORE FIRST USE 6 FILTER INSTALLATION 6 CONTROL PANEL 7 CARE AND MAINTENANCE 8 CLEANING THE APPLIANCE 8 FILTER REPLACEMENT REMINDER INDICATOR 9 TECHNICAL DATA 10 TROUBLESHOOTING 10 UK PRODUCT SUPPORT 11 2
SAFETY INSTRUCTIONS Important! • • • • • • • • • • • • • • • • • • • • • • • • • Carefully read the instructions before operating the unit. This appliance is for indoor use only. Rating: This unit must only be connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
depending on the air quality. Replace the filters regularly as instructed. INFORMATION ON INDOOR POLLUTANTS VOC (Volatile Organic Compound) – VOC’s come from motor vehicle exhausts, gasoline vapour, pollutants such as formaldehyde, ammonia and many other common and chemical solvents such as paints and glues. They can also be a by-product of mould growth. VOC’s cause irritation to the eyes and/or nose as well as causing headaches, nausea, and can even lead to damage to the central nervous system.
INTRODUCTION The EAP400D features an easy to use touch control panel, and provides 6 stages air purification using professional air filtration and sterilisation. • • • • • • • Advanced activated carbon filter - Removes unpleasant odours and absorbs harmful substances such as formaldehydes and benzenes. True HEPA filter - Removes 99.97 % of airborne particles which are 0.25 micrometres or larger. VOC filter - Removes toxic volatile organic compounds and unpleasant smells.
OPERATION BEFORE FIRST USE The EAP400D uses a combination of two filter units, which should be installed in the air purifier before operating for the first time. When inserting the filters, the “AIR FLOW” Activated carbon and Photo catalyst Antimicrobial and HEPA label should be pointing outwards. INSTALLING AND REPLACING THE FILTERS 1. Disconnect the power from the appliance. 2. Remove the right filter cover, by unclipping at the base. 3. Remove both of the filters from inside of the unit. 4.
CONTROL PANEL POWER BUTTON: TIMER BUTTON: Press to turn the unit on and off The air purifier can be timed to operate for intervals of 2, 4 or 8 hours, stopping automatically when the selected duration has elapsed. With the unit operating, repeatedly press the TIMER button to select the required timer duration. The LED lights will indicate the remaining operating time. To cancel the timer, repeatedly press the TIMER button until none of the timer lights are illuminated.
CARE AND MAINTENANCE Always turn off the appliance and unplug from the mains before cleaning or performing any maintenance. Unplug the appliance while not in use. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. CLEAN THE EXTERNAL CASE Only use tepid water and a mild detergent on a soft cloth. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Avoid wetting the power socket or cable.
FILTER REPLACEMENT REMINDER INDICATOR When the filters are due for replacement, the SPEED indicator will start to flash. Once the filters have been replaced following the steps in the “INSTALLING AND REPLACING THE FILTERS” section, hold down the TIMER button for five seconds, until the unit bleeps to register the new filters. CLEAN OR REPLACE THE FILTERS 1. If necessary wipe the inside of the filter cavity with a dry cloth. 2.
TECHNICAL DATA Model EAP400D-V2 Fan Speed Low Medium High Airflow (m3/hr) 70 100 150 Noise level (db) 25 32 40 Power rating 36 Watts / 220-240 V, 50 hz Ioniser 5x106 ions/cm3 Power cord length ≥ 1.4 meters Net Size (WxDxH) 329x170x300 mm Net Weight 3.2 kgs VOC and HEPA Filter Size (WxDxH) Efficiency Particle Size Life Time 20.9×10.2×4cm 99.9% ≤0.0003 mm about 6 months Carbon Activated and Photo catalyst Filter Size (WxDxH) Material Active Filter Absorption Surface 20.3×9.
Disposal: Do not dispose of this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.