USER MANUAL electriQ PORTABLE AIR CONDITIONER ECOSILENT12 ECOSILENT12E 12,000 BTU ECOSILENT14 14,000 BTU Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY 2 FEATURES AND PARTS LIST 4 INSTALLATION 5 OPERATION 7 REMOTE CONTROL 8 SMART INDICATOR 8 EMPTYING THE INTERNAL WATER TANK 9 CLEANING AND MAINTENANCE 10 TROUBLESHOOTING 11 ERROR CODES 11 SUPPORT 12 TECHNICAL SPECIFICATION 13 1
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit • This appliance is for indoor use only. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. • This air conditioner has been tested and is safe to use.
• R290 refrigerant gas complies with European environmental directives. • R290 has a low GWP (Global Warming Potential) of 3. • The air conditioner contains about 300 g of R290 refrigerant gas. • Do not use or store in an unventilated space with an area smaller than 14.4 m2 per unit.
FEATURES AND PARTS LIST • • • • • • • • • • 3 in 1 Cooling, Fan, Dehumidifier great for Rooms up to 30 sqm. 5 speed DC fan: balancing quiet operation with performance. SmartCool Logic for Improved Energy Efficiency. HEPA Filter for Air Purification 24 Hours Start / Stop Timer Digital Thermostat. Auto-Restart to retain the settings in the event of power failure.
INSTALLATION WARNING: Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. 1. Attach the fishtail connector to the end of the hose, by extending the end and twisting until firmly attached (At least 3 full rotations). 2.
INSTALLING THE HEPA FILTER (OPTIONAL) The air conditioner can accommodate a HEPA filter which will purify the air expelled back into the room in any operating mode. These can be purchased from the stockist using the code: FIL-ECOSILENTHEPA. The HEPA filter should be unwrapped and installed in the upper air inlet. To install, remove the upper filter frame from the air conditioner by pressing the two clips on the top of the filter frame.
OPERATION Press the POWER button to turn the unit ON or OFF. Press the MODE button to cycle between the 4 modes, the indicator for the selected mode will be illuminated. COOL: The room is cooled with the cold air expelled through the front air outlet while hot air is expelled through the vent pipe. The desired room temperature can be set between 17 and 30 degrees using the + and – buttons, and the fan speed can be changed using the SPEED button.
REMOTE CONTROL POWER TIMER DOWN UP SLEEP SWING ⁰C/⁰F FAN COOL DRY HIGH MID LOW Press to turn the unit on or off. Press to set the timer. Press to decrease the desired temperature or timer duration. Press to increase the desired temperature or timer duration. Press the sleep button to enter sleep mode. Press swing to turn the swing function on or off. Press to change between displaying the temperature in Celsius or Fahrenheit. Press to enter fan / air purify mode. Press to enter cool mode.
MULTI PROTECTIVE FUNCTIONS FROST PROTECTION In COOL, DRY or SMART COOL modes, if the temperature of the exhaust is too low, the machine will automatically stop operating until the temperature has risen. OVERFLOW PROTECTION When the water in the internal water tank exceeds the warning level, the machine will stop operating and sound an alarm with the LCD display showing “E7”. To resume operation empty the internal water tank.
MAINTENANCE AND CLEANING PLEASE TURN OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE CLEAN THE SURFACE Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc; otherwise, as this may cause damage to the surface and or the internal workings of the machine AIR FILTER CLEANING If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced.
TROUBLESHOOTING Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here. Problems The air conditioner does not work. The cooling effect is not good Reasons Solutions There is no electricity. Turn it on after connecting it to a socket with electricity. The display shows "E7". Discharge the water inside.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
TECHNICAL DATA Model Cooling capacity: Input power: Fan EcoSilent14 4100 W 1550 W EcoSilent12 EcoSilent12E 3520 W 1330 W DC motor with 5 fan speeds. Air flow volume: 400 m³/h Input current: 6.8 A 5.8 A Refrigerant: R290/300g Sound power level: 63 dB(A) Thermostat: 17-30oC Maximum working pressure of 1.0/3.5 MPa suction/exhaust side: Maximum Allowable Pressure 3.