User Manual
PRODUCT OVERVIEW
6
HOW IT WORKS
COOLING MODE
The compressor (6) in the external unit compresses the refrigerant into a high-temperature, high-pressure
gas. When this gas flows along the cooling fins of the condenser (7), heat is exuded and the gas condenses
into a liquid, which is then led to the evaporator (1) in the indoor unit. The liquid expands into a gas at a low
temperature and low pressure. This gas absorbs the warmth of the air in the room, and a fan (3) draws the
air through the filter and over the evaporator (1), blowing the cooled air back into the room. The heat is
moved to the compressor along with the gas. A fan (8) draws air over the condenser and blows the warm air
away.
1. Evaporator
2. Filter
3. Evaporator Fan
4. Gas Line
5. Liquid line
6. Compressor
7. Condenser
8. Condenser Fan
HEAT PUMP MODE
The system operates in reverse: the condenser works as an evaporator, the evaporator as a condenser:
warm air is blown into the room. It is ideal as a maintenance heating when outside temperature is not too
low and when the indoor temperature is more than 7°C.
DEHUMIDIFYING
As with cooling, the moisture in the air condenses on the cold evaporator at room temperature
acting as a powerful dehumidifier.
3
1
2
1
4
5
6
8
7