43
TECHNICAL SPECIFICATION
Model
eiQ-CRFC18K-V4
Indoor Rated voltage and frequency (Ph-V-Hz)
N/A
Outdoor Rated voltage and frequency (Ph-V-Hz)
1Ph/220-240V~/50Hz
Indoor Fuse Required
N/A
Outdoor Fuse Required
16A
Mode
Cooling
Heating
Rated capacity (KW)
5.3 (2.0-5.6)
5.9 (2.5-6.0)
Power input (W)
1555 (420-2100)
1445 (500-1940)
Current input (A)
2.1-10.1
2.5-9.2
SEER/SCOP(W/W)
6.1 / A++
4.0 / A+
Nominal load (kW)
5.300
4.800
Balance point temperature heating (
o
C)
-
-7
Min. outdoor operating temperature (
o
C)
-15
-15
Thermostat-off mode (W)
45
11
Standby mode (W)
1
Off mode (W)
1
Annual consumption (kW)
319
1765
Copper Pipe Type length
-
Liquid side / Gas side (mm/inch)
Φ6.35/Φ12.7
Max. refrigerant pipe length
15
Max. elevation
8
Interconnecting Cable
4x2.5mm
2
Moisture Removal (L/h)
2.47
Indoor
Air Flow (m
3
/h)
650
Body Dimensions (L*W*H) (mm)
565x267x565
Panel Dimensions (L*W*H) (mm)
650x29.8x650
Body Packaging (L*W*H (mm)
745x375x675
Panel Packaging (L*W*H (mm)
750x95x750
Body Net / Gross weight (Kg)
16.5/21.5
Panel Net / Gross weight (Kg)
2.7/4.0
Noise – Sound pressure level (dB/A)
36-43
Noise – Sound power level (dB/A)
46-55
Outdoor
Dimension (L*W*H) (mm)
925x366x700
Packaging (L*W*H) (mm)
990x410x770
Net / Gross Weight (Kg)
45/48
Noise – Sound pressure level (dB/A)
52
Noise – Sound power level (dB/A)
63
Refrigerant type/weight
R32 / 1300g
Defrost mode
Automatic defrosting
Applicable climate types
Cooling (-15
o
C – 50
o
C)
Heating(-15
o
C – 30
o
C)
Due to continuous product development process specification may change.
These units contain a gas governed by F-Gas regulations. The gas must be handled by qualified F-Gas engineers.