USER MANUAL COOKER HOOD TOUCH CONTROL COOKER HOOD eiQ60touchslimhe/eiQ90touchslimhe Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY 3 PRODUCT OVERVIEW 5 VENTILATION 6 INSTALLATION 7 OPERATION 9 FILTER CLEANING AND REPLACEMENT 10 BULB REPLACEMENT 11 CLEANING AND MAINTENANCE 11 TROUBLESHOOTING 12 SUPPORT 12 PRODUCT FICHE 14 2
SAFETY PRECAUTIONS Whilst this product is compliant with all safety requirements, incorrect or inappropriate use can lead to both personal injury and potential damage to property. Please read the contents of this instruction booklet thoroughly before fitting or using this appliance. • The cooker hood must be installed in accordance with the installation instructions and all measurements followed. • All installation work must be carried out by a competent person or qualified electrician.
• The minimum distance between the surface of the hob and the lowest part of the hood should be at least 65cm. A distance of between 65cm and 75cm gives peak efficiency. • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels. • When the hood is vented externally and used with appliances which burn fuel (e.g. gas, oil, wood) the area must be sufficiently ventilated to ensure safe operation.
PRODUCT OVERVIEW 5
INSTALLATION (VENT OUTSIDE) MOUNTING OF THE V-FLAP If the cooker hood does not have an assembled V-flap 1, you should mount the halfparts to its body.The images only show an example of how to mount the V-flap,the outlet may be various according to different models and configuration. To mount the V-flap 1 you should: 1. 2. 3. 4.
OPTIONS FOR VENTILATION This hood can be set up for either external venting or recirculation of the air. The type of setup should be decided before commencing installation. INSTALLATION If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe or nonflammable material with an interior diameter of 150mm) 1. Before installation, turn the unit off and unplug it from the outlet. 2.
4. Put the v-flaps and converter onto the hood, fix the expansion pipe (not supplied) with cable tie on the outlet.Then hang the hood on to the hook. See pic 3. 5. Fix the outside chimney bracket on the outside chimney with 2 pcs ST4*8mm screws, and be sure that the inside chimney can be adjusted the height in it freely. Afterwards, install chimneys on the cooker hood. Lay the expansion pipe to the wall outlet. Fix the expansion pipe with the cable tie on the wall-outlet .See Pic4. 6.
HINTS FOR EXHAUST DUCT INSTALLATION The following rules must be strictly followed to obtain optimal air extraction: • Keep expansion pipe short and straight. • Do not reduce the size or restrict expansion pipe. • When using expansion pipe always install the pipe pulled taut to minimize pressure loss. • Failure to observe these basic instructions will reduce the performance and increase noise levels of the cooker hood.
INSTALLING GREASE MESH FILTERS • To install filters for the following four steps. • Angle the filter into slots at the back of the hood. • Push the button on handle of the filter. • Release the handle once the filter fits into a resting position. • Repeat to install all filters.
BULB REPLACEMENT Before changing the bulb, ensure the hood is turned off and the power is disconnected before attempting to change the bulb. Wait until the flitting has cooled down before commencing replacement. • Open the LED light plate assembly and take away the grease filter.See pic 1. • Find the light wire at the back of the wire outlet.Then slightly pull the light connecting wire out, and dismantle the terminal of the light connecting wire. See pic 2.
TROUBLESHOOTING Fault Light on, but motor does not work Light does not work, motor does not work Oil leakage Lights not working Insufficient suction The Cooker hood inclines Possible Cause Solution Fan switch turned off Select a fan switch position. Fan switch failed Contact service center. Motor failed Contact service center. House fuses blown Reset/Replace fuses. Power cord loose or disconnected Refit cord to power outlet. Switch power outlet on.
INFORMATION FOR DISMANTLING Do not dismantle the appliance in a way which is not shown in the user manual. The appliance could not be dismantled by user. At the end of life, the appliance should not be disposed of with household waste. Check with your Local Authority or retailer for recycling advice. electriQ UK SUPPORT www.electriQ.co.uk/support Call: 0330 390 3061 Office hours: 9AM - 5PM Monday to Friday www.electriQ.co.
PRODUCT FICHE Model Identification eiQ60TOUCHSLIMHE eiQ90TOUCHSLIMHE Symbol Value AEChood 16.1 Unit kWh/A Annual Energy Consumption Standard Annual Energy SAEChood 51.2 kWh/a Consumption Time increase factor F 0.6 Fluid Dynamic Efficiency FDEhood 37.9 Energy Efficiency Index EEIhood 31.4 Measured air flow rate at QBEP 319.1 m3/h best efficiency point Measured air pressure at PBEP 264 Pa best efficiency point Maximum air flow Qmax 480.3 m3/h Measured electric power WBEP 61.