USER MANUAL COOKER HOOD eiq90chimbl / eiq90chimss Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY 3 OPTIONS FOR VENTILLATION 5 PARTS 6 INSTALLATION 7 OPERATION 12 CLEANING AND MAINTENACE 12 BULB REPLACEMENT 13 TROUBLESHOOTING 14 SUPPORT 15 TECHNICAL SPECIFICATION 16 2
SAFETY PRECAUTIONS Whilst this product is compliant with all safety requirements, incorrect or inappropriate use can lead to both personal injury and potential damage to property. Please read the contents of this instruction booklet thoroughly before fitting or using this appliance. • The cooker hood must be installed in accordance with the installation instructions and all measurements followed. • All installation work must be carried out by a competent person or qualified electrician.
• The plug must be accessible after installation for isolation in case of an emergency – or an appropriate fused switch if the unit is hard-wired to the mains via a spur. • The minimum distance between the surface of the hob and the lowest part of the hood should be at least 65cm. A distance of between 65cm and 75cm gives peak efficiency. • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
OPTIONS FOR VENTILATION This hood can be set up for either external venting or recirculation of the air. The type of setup should be decided before commencing installation. EXTERNAL VENTING If you have an outlet to the outside, your cooker hood can be connected as shown in the diagram using any suitable extraction duct (enamel, aluminium, flexible pipe or inflammable material with an interior diameter of 150mm) can be used.
BEFORE USAGE Before usage, read all the instructions and make sure that the voltage (V) and the frequency (Hz) indicated on the identification plate (found inside the cooker hood) and all the data inside the appliance are exactly the same as the voltage and frequency in your home. Plug the power lead into the power socket (or if connecting directly to the mains via a switched spur, ensure the work is carried out by a competent, qualified person) and the cooker hood is then ready for use.
INSTALLATION 7
POSITIONING • The bending of the ventilation tube should be less than 120⁰. Ensure the installation plate is fixed horizontally to avoid grease and muck collecting at one end. • After installation, make sure that the power can be disconnected if necessary. • The cooker hood should be placed 650-750 mm above the cooking area. • There must be adequate ventilation of the room while the cooker hood is operating.
6 x Wall plugs Follow the diagram on the previous page for measurements and fix installation plate and screw two suspension screws (ST5*50) into the wall plugs. 4 x screws (ST5*50) If you are using an exhaust pipe (not included) fit the pipe before hanging the hood.
Hang the range hood on the previously installed suspension screws. Lock the suspension screws (ST5*50) into place to prevent the range hood from accidently falling during installation.
2 x Screws (M4*8) Fix the chimney into place with two M4x8 Screws. 2 x Screws (M4*8) Fix the inner chimney to the extension plate extension to the chimney with two M4x8 screws.
OPERATION Stop Low Mid High Light The motor will stop running The motor runs at low speed The motor runs at medium speed The motor runs at high speed Turn the light on and off MAINTENANCE Before cleaning, switch the unit off and pull out the plug, or switch off at the relevant mains switch if the unit has been hard-wired in. Make sure the unit has no power being fed to it. REGULAR CLEANING Use a soft cloth moistened with warm mildly soapy water or household cleaning detergent.
CHARCOAL FILTER REPLACEMENT Remove the metal grease filters. Remove the saturated activated charcoal filter. Fit the new filters. Replace the metal grease filters. LIGHT BULB REPLACEMENT Before changing the bulb, ensure the hood is turned off and the power is disconnected before attempting to change the bulb. Wait until the flitting has cooled down before commencing replacement. 1. Remove the aluminum grease filter from the hood. 2.
TROUBLESHOOTING Fault Cause Solution Light on, but fan does not work The fan blade is jammed. Switch off the unit. Repair to be carried out by qualified service personnel only. The motor is damaged. Both light and fan Light has blown. do not work Power cord loose. Grease or oil leaking from the underside of the hood Excessive Vibration Replace the lamp with correct rating. Plug in to the power supply again.
electriQ UK SUPPORT INFORMATION FOR DISMANTLING Do not dismantle the appliance in any way which is not shown in the user manual. The appliance must not be dismantled by an unqualified person. At the end of its life, the appliance should not be disposed of with general household waste. Check with your Local Authority or retainer for recycling advice. www.electriQ.co.uk/support Call: 0871 984 4416 Office hours: 9AM - 5PM Monday to Friday www.electriQ.co.
PRODUCT FICHE Model Identification eiQ90CHIMSS、eiQ90CHIMBL Symbol Value Unit Annual Energy Consumption AEChood 26.3 kWh/A Standard Annual Energy Consumption Time increase factor SAEChood 43.2 kWh/a F 1.4 Fluid Dynamic Efficiency FDEhood Energy Efficiency Index EEIhood Measured air flow rate at best QBEP efficiency point 15.8 60.9 188.2 m3/h Measured air pressure at best efficiency point PBEP 149 Pa Maximum air flow Qmax 333.