User Manual
6
EXTERNAL VENTING
If you have an outlet to the outside, your cooker hood can be
connected as shown in the diagram using any suitable
extraction duct (enamel, aluminium, flexible pipe or
inflammable material with an interior diameter of 150mm) can
be used.
An adaptor is supplied to enable you to connect your hood to
pre-existing 120mm diameter ducting.
If this is the chosen installation method consideration to the
route of the vent pipe should be made prior to installation.
RECIRCULATION
This cooker hood also supports the recirculation of air once it has
passed through the filters. The filtered air is then expelled
through the vent holes in the side of the chimney.
When setting the unit up in this configuration, carbon filters should
also be used to remove odours from the air. Details of sourcing
and fitting the filters can be found in the Carbon filter section.
When setting up for recirculation the installation instructions should
be followed, but a vent pipe should not be attached, and instead
the air can be routed back into the room through the top of the unit.
UNPACKING YOUR APPLIANCE
• Please take great care when unpacking; a sharp blade should not be used to
open the box, as it may go deep enough inside to damage components.
Components damaged or marked by careless unpacking are not covered
under the guarantee.
• Carefully unpack the contents and check against the section below (Parts)
and the next section (Product overview).
• Packaging materials should be recycled in accordance with local regulations